Applications
Over-under units are space savers and provide for installation in tight areas.
One common inlet/outlet for both filter and regulator saves on piping costs.
Features
10-250 PSIG adjusting range for metal bowl with sight glass
5 micron element
1.72 oz. bowl
Self-relieving standard
Spring-loaded diaphragm
Metal bowl supplied with GC240 gauge
5 – 125 PSIG adjusting range for transparent bowl with guard
Transparent Bowl supplied with GC230 gauge
Safety Notes
FRL’s are designed for air service only, unless otherwise indicated.
SCFM ratings at 100 PSIG inlet pressure
Designed for air service only!
Use
To increase regulated pressure, pull adjusting knob and turn clockwise. To reduce pressure, turn knob counter clockwise. To lock knob, push down.
Two 1/4″ gauge ports located on the front and rear faces of the body. These ports may be used as additional regulated ports or for pressure gauges. Plug unused port(s).