RKI SDM-2012 Calibration Station
GX-2012 Calibration Station
Stand Alone Calibration Station
Features
Stand Alone Station
- Stand-alone station (no PC Required)
- Charging (Li-Ion Battery Pack)
- Calibration
- Bump Test
- Save Bump Test and Calibration records
- Bump test and calibration records copy to USB jump drive
- Includes PC software for viewing/ archiving bump test and calibration records
Categories: Area Gas Detectors & Wireless Solutions, Gas and Flame Detection
Tags: calibration station, gas detection, gas detector, gas monitor, portable gas monitor
Brand RKI
Description
SDM-2012 Datatsheet [PDF]
SDM-2012 User Guide [PDF]
SDM-2012 Calibration Station Standalone Configuration Manual [PDF]
SDM-2012 PC Controlled Configuration Manual [PDF]
RKI’s new SDM-2012 calibration station for the GX-2012 is now available with advanced features for charging, calibration, & bump testing. Once you power up the GX-2012 inside the SDM-2012 calibration module, the GX-2012’s display will indicate whether it’s transmitting data, bump testing, calibrating, as well as the results of the bump test or calibration.
Multi Module System
The SDM-2012 can also be connected to a PC for automated calibration, bump testing, and archiving of logged data including calibration and bump test records, interval and alarm trends. Network up to 10 SDM-2012 stations to charge, calibrate, and bump test 10 instruments simultaneously.
User Guide Poster
Each SDM-2012 ships with a pictoral wall chart user guide. This guide gives the already easy-to-use cal station a simple pictorial easy step by step guide to calibrating or bump testing a GX-2012. It’s ideal to hang in an instrument shop or wherever the GX-2012 is located.
Application
Multi Module System
- Multiple modules connected to a PC (10 max)
- Charging
- Calibration
- Bump Test
- Configure GX-2012 parameters
- 2 Calibration gas ports
- Archive Bump Test and Calibration records
- Archive data to network location
- Software controlled data retrieval
- Automatic calibration/bump test option
- Windows 7 compatible
Specifications
|
Input Power |
12 VDC NOTE: AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 12 VDC, 1.2A output provided as standard. |
|
Environmental Conditions |
• For Indoor Use Only • -10° C to 40° C, below 80% Relative Humidity, Non-Condensing |
|
Applicable Instruments |
GX-2012 and Gas Tracer |
|
Maximum Number of Records Saved |
200 (stand-alone) |
|
Number of Calibration Gas Cylinders |
Up to two calibration gas cylinders per bump test or calibration at a time |
|
Standard Accessories |
|
Specifications subject to change without notice
Ordering Info
|
Docking Station |
|
|
81-SDM2012-01 |
Single point calibration station for GX-2012, model SDM-2012 with AC Adaptor, flash drive, USB cable, tubing & installation CD |
|
81-SDM2012-02 |
Single point calibration station for GX-2012, model SDM-2012 with AC Adaptor, flash drive, USB cable, tubing installation CD & demand flow regulator |
|
81-SDM2012-03 |
Single point calibration station for GX-2012, model SDM-2012 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 58AL cyl H2S (25 ppm)/CO/CH4/O2 |
|
81-SDM2012-04 |
Single point calibration station for GX-2012, model SDM-2012 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator, 58AL cyl H2S (25 ppm)/CO/CH4/O2 & 58L steel cyl Methane 100% volume |
|
81-SDM2012-05 |
Single point calibration station for GX-2012, model SDM-2012 with AC Adaptor, flash drive, USB cable, tubing, installation CD, two demand flow regulators, 58AL cyl H2S (25 ppm)/CO/CH4/O2 & 58L steel cyl Methane 100% volume |
|
Calibration Equipment and Accessories |
|
|
81-0013RK-05 |
Cylinder, Methane, 50% volume in N2, 58L steel |
|
81-0016RK-05 |
Cylinder, Methane 100% volume, 58L steel |
|
81-0078RK-03 |
Cylinder, N2 100%, 103L |
|
81-0085RK-01 |
Cylinder, Methane, 1000 ppm in Air, 34L |
|
81-0085RK-03 |
Cylinder, Methane, 1000 ppm Air, 103L |
|
81-0089RK-03 |
Cylinder, CO 50 ppm / Hexane 15% LEL / O2 12 % in N2, 103L |
|
81-0090RK-01 |
Cylinder, CO 50 ppm / Methane 50% LEL / O2 12 % in N2, 34L |
|
81-0090RK-03 |
Cylinder, CO 50 ppm / Methane 50% LEL / O2 12 % in N2, 103L |
|
81-0151RK-02 |
Cylinder, H2S 25 ppm in N2, 58AL |
|
81-0154RK-02 |
Cylinder, H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 58AL |
|
81-0154RK-04 |
Cylinder, H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 34AL |
|
81-1054RK |
Regulator, demand flow for 34AL/58AL/103L |
|
81-1055RK |
Regulator, demand flow for 17L/34L steel cylinders |
|
81-0155RK-02 |
Cylinder, H2S 25 ppm / CO 50 ppm / HEX 15% LEL / O2 12% in N2, 58AL |
|
82-6050RK |
USB Hub, 4 port 2.0 for SDM-2012 |
|
82-6051RK |
USB Hub, 7 port 2.0 for SDM-2012 |
|
71-8007RK |
SDM-GX Product CD |
Specifications subject to change without notice.