Description

Applications

Specifically designed for liquid terminal operation on batch loading and overfill protection, tank cars, tank trucks, marine barges, suitable for open and close dome

Specifically designed for liquid terminal operation on batch loading and overfill protection, unloading, tank cars, tank trucks, marine barges, suitable for open and close dome

Available Options

  • 24″, 36″, 48″ and 60″ probe lengths standard, other lengths available
  • Optional opto-isolated solid state contact output
  • 24″, 36″, 48″ and 60″ probe lengths standard, other lengths available

    Construction

    Wetted materials: 316 stainless steel, PTFE standard, other materials available

    Features

  • Totally self-contained; no wires, tubing or external power
  • Rugged weather and corrosion resistant construction
  • No moving parts, tip sensitive phase shift™ digital capacitance sensor for conductive and non-conductive fluid
  • Requires no calibration or adjustment
  • Operates up to 2500 hours on a single 9V alkaline battery
  • Adjustable insertion length through a standard 1/2″ NPT fitting
  • High intensity audible and flashing visual outputs
  • Full, hard graduated laser engraved rod
  • Fail safe continuous battery monitor goes to alarm state on low battery
  • Activation point 1/4″ above liquid surface
  • Battery current drain <0.23 ma during standby; <50 ma in alarm state
  • Horn intensity 101 dB at 2′
  • Light output 3 each 3000 mcd high intensity flashing LED’s
  • Capacitance Phase Shift Probe
  • 1/2 NPT gland standard
  • Minimum dielectric constant 1.8
  • No moving parts, tip sensitive phase shift™ digital capacitance sensor for conductive and nonconductive fluid, conductivity sensor with integral splash shield
  • A100 operates up to 2500 hours n a single 9V alkaline battery
  • Specifications

    Intrinsically safe design per ANSI/UL913 Class I, Div I Groups A, B, C and D Hazardous Areas

  • Intrinsically safe design per ANSI/UL913 Class I, Div I Groups A, B, C and D Hazardous Areas
  • Minimum dielectric constant 1.7
  • Temperature range: capacitance probe: -14°F to 250°F (-26°C to 121°C)
  • Compatible with any liquid or dry bulk material with a dielectric constant of 1.7 or greater
  • Pressure rating on standard unit: 50 PSI, consult Dixon® for applications up to 300 PSI
  • Additional information
    Optional Package/Box Quantity

    Temperature Range

    Length

    ,

    ,

    ,

    ,

    ,

    ,

    ,

    Pressure Rating