Controller MX 52
- 2-16 channels
- SIL2 according to EN61511
- 2 discrete alarm relays per channel, 1 common Alarm 3 relay, 1 common Fault relay
- Keyboard or PC setup
- RS 485 output
Categories: Controllers, Gas and Flame Detection
Tags: controller, flame detection, gas detection
Brand Teledyne
Description
The MX 52 control unit allows various detectors to be connected and monitored. Any gas detector from Teledyne Gas and Flame Detection or any other 4-20 mA device can be monitored and controlled.
The modular design and flexibility enable this MX 52 gas detection equipment to be adapted to your exact requirements.
| Type: | MX52 |
| Function: | Controller Safety Instrumented System |
| Capacity: | 8 cards, 2 independent channels each (max 16 channels) |
| Display: | Fluorescent 2 lines 16 fixed or scrolling characters |
Alarms |
|
| Fault Alarms: | Specific channel identification with yellow LED Common fault relay |
| Gas Alarms: | 3 independent thresholds per channel Third threshold on delay or average Automatic or manual reset Programmable increasing or decreasing alarm Visual red LED |
| Audible Alarms: | Follows the fault sequence and panel acknowledgement gas alarm |
| Outputs: | 2 independent gas alarm relays per channel (2 A – 250 VAC rating for resistive load) 1 common alarm 3 relay 1 common fault relay Energized or de-energized alarm relays Energized fault relay Programmable NC or NO on alarm 1, alarm 2 and fault alarm, SPDT on alarm 3 |
Inputs |
|
| Type of detectors: | Flammable catalytic bridge type – 3 wires Oxygen, toxic or flammable analog transmitters, 2 or 3 wires Other 4-20 mA analog output transmitters |
| Wiring: | 2 or 3 wires shielded cable |
| Loop impedance: | Flammable 3 wires: 32 Ω 4-20mA; 2 or 3 wires: 56 Ω Average line length (in meters at 20°C, core size 1,5 mm2): Flammable: Bridge type – 1000 m 4-20 mA – 2000 m |
| Signal Output: | 4-20 mA per channel Serial RS 485 or 232 MODBUS protocol |
| Power supply: | 103 to 122 Vac or 207 to 244 Vac 21 to 31 VDC Power consumption: 300 VA or 240 W |
| Miscellaneous: | Local or remote acknowledgement Operating temperature: -10 to +45°C Relative humidity: 5 to 95% non condensing |
| Dimensions: | Rack 3U, 19” frame Dimensions:482 w x 132 h x 266 d in mm |
| Weight: | 15 Kgs |
Approvals |
|
| Compliant with European standards EN 50054, EN 50057, EN 50104 and EN 50271 (harmonized standards 61779-1: 2000 and 61779-4: 2000) ATEX II(2)G SIL 2 capability according to EN 61511 (INERIS n° 68210-2005) EMC Directive EN 50081-1-2 and EN 50082-1-2 Low voltage directive EN 61010-1 |
|
Gas detection equipment MX52 controller